X8011-II PCB – MXI

Features

High-performance X-ray inspection for SMT/electronics

  • Fully manual or in-line-compatible inspection mode
  • Optional open high-performance tubes or low-maintenance closed tubes
  • Highest magnifications and excellent image quality
  • High-resolution digital flat panel detectors
  • EasyClick principle for easy mounting of handling units
  • Upgradeable with Viscom computed tomography
Viscom-Plus
  • Reliable short-cycle inspections
  • Robust inspection strategies using the Viscom standard library for solder joint inspections
  • Customer-specific software adaptations possible 
  • Over 20 years of AXI experience included
  • Separate analysis software for BGA, surface defects, THT, QFN
  • Independent real-time image processing with Viscom analysis tools
  • Intuitive operation and comprehensive analysis features of Viscom XMC and Viscom SI
Specifications
X8011-II PCB
eco
| X8011-II PCB
plus
| X8011-II PCB 
flex
X-ray technologyX-ray tubeSealed direct beam tube or open microfocus transmission tube
(optionally also TXD X-ray tube, < 1.5 μm)
High voltage
10–130 kV / 10–160 kV / 10–200 kV
X-ray current
50–300 μA / 5–1000 μA
Target powermax. 20 W / max. 40 Wmax. 40 W
Geometric magnificationmax. 35 times / max. 2650 timesmax. 2650 times
Image converterHigh resolution
7.3" FPD, 14 bit
High resolution
11" FPD, 14 bit
Proven resolution< 16–50 μm / < 4 μm< 4 μm
Detector swivel range
Additionally via the
rotation and tilt axis +/- 45° (90°)
0–60°0–60°
X-ray cabinetDesigned to meet requirements for fully protected devices in
accordance with RöV (German X-ray Regulation), CE mark and
additional international standards.
Radiation leakage rate < 1 μSv/h
SoftwareUser interfaceViscom XMC / Viscom SI optional
Available software packages

BGA analysis software
QFN analysis software
THT analysis software
ACA analysis software (surface analysis)
Fully automatic Viscom SI analysis software

XVR-CT software
Verification station Viscom HARAN
Viscom Quality Uplink to AOI, AXI, and SPI from Viscom
for process optimization

System computerOperating systemWindows®
MonitorHigh-resolution 24" LED display for special depiction of grayscale values in the SMT and 
electronics sectors
Sample handlingManipulatorX-Y-ZX-Y-Z plus rotation module
Max. table travel rangeHorizontal X/Y-axis: 460 x 435 mm (18.1" x 17.1")
Vertical Z-axis: 290 mm (11.4")
Max. rotation module travel range-X8011-II PCB plus, X8011-II flex
Horizontal X/Y-axis: 350 x 430 mm (13.8" x 16.9")
Vertical Z-axis: 290 mm (11.4")
n x 360°
Max. sample weight10 kg (22 lbs) (with rotation module, 5 kg/11 lbs)
Sample changeManual or motorized window opening
Optional additional axes availableYes
Other system data
Connection values230 V, 1 P/N/PG, 16 A
System dimensionsApprox. 1144 x 2007 x 1453 mm (W x H x D) (45" x 79" x 57.2")
WeightApprox. 2100 kg (4630 lbs)