X8011-II PCB – 3D MXI
Features
High-performance X-ray inspection for SMT/electronics
- Fully manual or in-line-compatible inspection mode
- Optional open high-performance tubes or low-maintenance closed tubes
- Highest magnifications and excellent image quality
- High-resolution digital flat panel detectors
- EasyClick principle for easy mounting of handling units
- Upgradeable with Viscom computed tomography
Viscom-Plus
- Reliable short-cycle inspections
- Robust inspection strategies using the Viscom standard library for solder joint inspections
- Customer-specific software adaptations possible
- Over 20 years of AXI experience included
- Separate analysis software for BGA, surface defects, THT, QFN
- Independent real-time image processing with Viscom analysis tools
- Intuitive operation and comprehensive analysis features of Viscom XMC and Viscom SI
Specifications
X8011-II PCB eco | | X8011-II PCB plus | | X8011-II PCB flex | |||
---|---|---|---|---|---|
X-ray technology | X-ray tube | Sealed direct beam tube or open microfocus transmission tube (optionally also TXD X-ray tube, < 1.5 μm) | |||
High voltage | 10 - 130 kV / 10 - 160 kV / 10 - 200 kV | ||||
X-ray current | 50 - 300 μA / 5 - 1000 μA | ||||
Target power | max. 20 W / max. 40 W | max. 40 W | |||
Geometric magnification | max. 35 times / max. 2650 times | max. 2650 times | |||
Image converter | High resolution 7.3" FPD, 14 bit | High resolution 11" FPD, 14 bit | |||
Proven resolution (at 90 kV/80 μA) | < 16 - 50 μm / < 4 μm / < 1.5 μm | ||||
Detector swivel range Additionally via the rotation and tilt axis +/- 45° (90°) | 0° | 0–60° | 0–60° | ||
X-ray cabinet | Designed to meet requirements for fully protected devices in accordance with RöV (German X-ray regulation), CE mark and additional international standards for worldwide use. Radiation leakage rate < 1 μSv/h | ||||
Software | User interface | Viscom XMC / Viscom SI optional | |||
Available software packages | BGA analysis software XVR-CT software (planar, rotary) | ||||
System computer | Operating system | Windows® | |||
Monitor | High-resolution 24" LED display for special depiction of grayscale values in the SMT and electronics sectors | ||||
Sample handling | Manipulator | X-Y-Z | X-Y-Z plus rotation module | ||
Max. table travel range | Horizontal X/Y-axis: 460 x 435 mm (18.1" x 17.1") Vertical Z-axis: 290 mm (11.4") | ||||
Max. rotation module travel range | - | X8011-II PCB plus, X8011-II flex Horizontal x/y-axis: 350 x 430 mm (13.8" x 16.9") Vertical z-axis: 290 mm (11.4") n x 360° | |||
Max. sample weight | 10 kg (22 lbs) (with rotation module, 5 kg/11 lbs) | ||||
Sample change | Motorized window opening | ||||
Optional additional axes available | Yes | ||||
Other system data | |||||
Power requirements | 230 V (other voltages on request), 1P/N/PE, 16 A | ||||
System dimensions | Approx. 1144 mm x 2007 mm x 1420 mm (W x H x D) (45" x 79" x 55.9") | ||||